SAE J516 pdf download
SAE J516 pdf download.(R) Hydraulic Hose Fittings.
This SAE Standard provides general and dimensional specifications for the most common hose fittings used in oonlunction with hydraulic hoses specified m SAE J517 and utilized in hydraulic systems on mobile and stationary equipment.
The general specifications contained in Sections 1 through 15 are applicable to all hydraulic hose fittings and supplement the detaHed specifications for the 1OOF-sefles fittings contained in the later sections of this document.
This document shall be utilized as a procurement document only to the extent agreed upon by the manufacturer and user.
Refer to SAE J517 for specifications of hose and information on hose assemblies. SAE J1273 contains infoimation on application factors affecting hose fittings, hose, arid hose assemblies.
ThE RATED WORKING PRESSURE OF A HOSE ASSEMBLY COMPRISING SAE J516 FITTINGS AND
SAE J517 HOSE SHALL NOT EXCEED ThE LOWER OF THE TWO WORKING PRESSURE RATED
VALUES.
1.1 Rationale
This document has been completely revised to reflect the metnc system. Tables have been simplified by having only one max length per fittinWhose size combination- Also limited the number of jump sizes and drops. Added optional inch hex sizes, Added the idenification information (Paragraph 4).
The following are hose fitting types contained in this document:
a. Male dryseal pipe thread hose fittings shall be as shown In Figure 1 (or the respective styles, and In Table 2 for the applicable hoses and sizes.
b. Male straight thread 0-ring hose fittings shall be as shown in Figure 2 or the respective styles, and in Table 3 for the applicable hoses and sizes.
c. Male 37 degree flare hose fittings shall be as shown m Figure 3 for the respective styles, and In Table 4 for the applicable hoses and sizes.
d. Female 37 degree flare hose fittings shall be as shown in Figures 4 to 48 for the respective styles and shapes, and in Tables 5 to 5B for the applicable hoses and sizes.
e. Male 45 degree flare hose fittings shall be as shown by the 37 degree figures arid tables.
f. Female 45 degree flare hose fittings shall be as shown by the 37 degree figures and tables.
g. Male flareless 24 degree cone hose fittings shall be as shown in Figure 5 and in Table 6 for the applicable hoses and sizes.
h. Female flareless 24 degree cone hose fittings shall be as shown in Figures 6 and in Table 7 for the applicable hoses and sizes.
i. 4-bolt split flange hose fittings shall be as shown in Figures 7 to 7F for the respective styles and shapes, and in Tables 8 to 8F for the applicable hoses and sizes.
I Female 0-ring face seal hose fittings shaH be as shown in Figures 8 to 8B for the respective styles, and Tables 9 to 9B for the applicable hoses and sizes.
It is recommended that where step sizes or additional types of fittings are required, they be designed to conform with the specifications of this document insofar as they may apply. The following general specifications shall supplement the dimensional data contained in the tables with respect to all unspecified detail.
2. References
2.1 ApplIcable PublIcations
The following publications form a part of the specification to the extent specified herern. Unless otherwise
indicated, the latest revision of SAE publications shall apply.
2.1.1 SAE PUBLICATIONS
Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.
SAE J475—Screw Threads
SAE J476—Dryseal Pipe Threads
SAE J512—Automotive Tube Fittings
SAE J514—Hydraulic Tube Fittings
S.AE J517—Hydraulic Hose
SAE J518—Hydrauhc Flanged Tube, Pipe, arid Hose Connections. 4-Bolt Split Flange Type
SAE J533—Flares for Tubing
SAE J846—Ccxing Systems for Identification of Fluid Conductors and Connectors
SAE J 1 273—Selection, Installation, and Maintenance of Hose and Hose Assemblies
SAE J 1402—Automotive Air Brake Hose and Hose Assemblies
SAE J1453—Fitting–O-Ring Face Seal
SAE J1453-1—Specihcation for 0-Ring Face Seal Fittings—Part 1: Tube Connection Details and Common Requirements for Performance and Tests
SAE J1926—Specification for Straight Thread 0-Ring Boss Port
2.1.2 ISO PUBUCATIONS
Available from ANSI. 25 West 43rd Street. New York, NY 10036-8002.
ISO 6162-1——Hydraulic fluid power—Flange connectors with split or one-piece flange clamps and metric or inch screws—Part 1: Flange connectors for use at pressures of 3.5 MPa (35bar) to 35 MPa (35Obar)
ISO 6162-2—Hydraulic fluid power—Flange connectors with split or one-piece flange clamps and metric or inch screws—Part 2: Flange connectors for use at pressures of 35 MPa (35Obar) to 4OMPa (400bar)
ISO 84342—Metallic tube connections for fluid power and general use—Part 2: 37 degree flared connectors
ISO 8434-3—-Metallic tube connections for fluid power and general use—Part 3:0-ring face seal connectors
ISO 1 1926-2——Connections for general use and fluid power—Ports and stud ends with ISO 725 threads and 0-ring sealing—Part 3 light-duty (L series) stud ends
ISO 1 1926-3—Connections for general use and fluid power—Ports and stud ends with ISO 725 threads and 0-ring sealing—Pan 2 heavy-duty (S series) stud ends
2.1.3 ASTM PUBLICATION
Available from ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959
ASTM B 117—Method of Salt Spray (Fog) Testing.