Home>ASME Standards>ASME B16.45-1998 pdf download

ASME B16.45-1998 pdf download

ASME B16.45-1998 pdf download.CAST IRON FITINGS FOR SOVENT DRAINAGE SYSTEMS.
(d) Connections shall conform to sites and dimensions listed in Table 1 or 2. Joint ConneCtions are designed for use with hublcss soil pipe couplings conforming to the requirements of the Cast Iron Soil Pipe Institute Specification 310-85.
3 SIZES
(a) Sizes and dimensions of fittings shall conform to dimensions in Table I or 2.
(b) Opening size sequence is illustrated in Figs. 3 and 4.
4 MARKING
(a) Each fitting shall be marked with the manufacturer’s name or trademark, and with Sovcnt®.
(b) Fittings of gray cast iron do not require material marking. If the manufacturer elects to use malleable iron or ductile iron, the fitting shall he marked with “NI I” or “II
5 MATERIAL
(a) The material used to manufacture the fittings shall be in accordance with ASTM A 126, Grade A.
(b) At the option of the manufacturer, fittings may be furnished of malleable iron complying with the requirements of ASTM A 197 or A 47, Grade 32510, or of ductile iron complying with ASTM A 395 or A 536, Grade 65-45-12.
6 PITCH
All nominal 9() deg drain openings shall be pitched down toward the fitting in a slope of ‘/4 in./ft (2.1%) of horizontal pipe with reference to a horizontal plane.
The use of the word “nominal” as a modifier of a dimension or size is intended to indicate that the stated dimension or site is used for purposes of designation only. The actual dimension may be the nominal dimension subject to the variation of established tolerances.
8.3 Outside and Inside Diameter of Fitting
The diameters shall be within the tolerances shown in Table 3.
8.4 Center-to-End Dimensions
The center-to-end dimensions shall be within the tolerances shown in Table 4.
9 ALIGNMENT
The maximum allowable variation in the alignment of all openings shall be 0.06 in./ft (0.5%), except for openings that are pitched.
10 TESTS
(a) Each fitting shall be subjected to a minimum hydrostatic pressure of 25 psi. The fitting shall not leak water or sweat at any part of the surface. Alternate tests that demonstrate the same degree of soundness and strength are acceptable.
(b) Manufacturers shall inspect fittings prior to shipment for the presence of cracks, holes, or other defects.
(c) Manufacturers shall be prepared to certify that their products meet the requirements of this Standard.