IEC 60335-2-16:2002 pdf download
IEC 60335-2-16:2002 pdf download.Household and similar electrical appliances -Safety – Part 2-16:Particular requirements for food waste disposers.
7.12.1 Addition:
The instructions shall state that the appliance must be installed so that reset buttons and
reversing switches are readily accessible,
8 Protection against access to live parts
This clause of Part 1 is applicable.
9 Starting of motor-operated appliances
This clause of Part us not applicable.
10 Power input and current
This clause of Part 1 Is applicable except as follows.
10.1 Addition:
The representative perrod is between the fifth second end the fifteenth second of operation.
10.2 Addition.’
The representative period is between the fifth second and the fifteenth second of operation.
11 HeatIng
This clause of Part 1 is applicable except as follows.
11.7 Replacement:
Appliances of the continuous-feed type are operated for 4 mm.
Appliances of the batch-feed type are operated for two periods of 2 miri with a rest period of
30 s during which they are switched off.
12 Void
13 Leakage current and electric strength at operating temperature This clause of Part I is applicable.
14 TransIent overvoltages
This clause of Part I is applicable.
15 Moisture resistance
This clause of Part 1 Is applicable except as follows.
15.2 leplacement;
Appliances shall be constructed so that obstruction of the outlet does not affect their electrical insulation.
Compliance is checked by the following test,
The outlet of the appliance is blocked and the sink filled with water to a depth of 200 mm, measured from the lowest point inside the sink. The appliance is supplied at rated voltage and operated until a protective device operates or for 15 mm, whichever is shorter. The appliance is operated again after a rest period of 15 mm,
The appliance shall then withstand the electric strength test of 16.3 and inspection shall show that there is no trace of water on insulation that could result in a reductIon of clearances and creepage distances below the values specified in Clause 29.
16 Leakage current and electric strength
This clause of Part I Is applicable.
17 Overload protection of transformers and associated circuits This clause of Part 1 Is applicable.
18 Endurance
This clause of Part I is not applicable.
19 Abnormal operation
This clause of Part 1 Is applicable except as follows.
19.7 ModifIcation:
Appliances are operated without water for
— 30 s. for continuous-feed types;
— 5 mm, for batch-feed types
19.9 Not applicable.
20 StabilIty and mechanical hazards
This clause of Part 1 is applicable except as follows.
202 Addition:
The test probe ss not applied to the inlet of the appliance.
20.101 Access to moving parts through the inlet opening shall be prevented unless the motor is automatically switched off when a cover Is removed.
Compliance is checked by inspection and by means of test probe 31 of IEC 61032 applied with a force of 50 N to the inlet opening. It shall not be possible to touch moving parts with the probe and they shall be located at least 100 mm from the top of the ,nlet.
NOTE I Tb. applianc• Is adjusted for the thinnesi sin& bottom
NOTE 2 Detachable part. preventing food waste from e,ng eiected ot preventing utensilS from falling into the grinding chamber are removed
20.102 Food waste shall not be ejected through the inlet opening.
Compliance is checked with the appliance supplied at rated voltage and operated under normal operatIon Pieces of the wooden cubes shall not be ejected into the sink,
21 MechanIcal strength
This clause of Part I is applicable.
22 Construction
This clause of Part I is applicable except as follows.
22.101 Appliances shall incorporate a protective d.vlc.
Compliance is checked by inspection.
22.102 The reset button of a protectiv, device shall be recessed or otherwise guarded.
Corn plance is checked by applying a rod In any direction when the contacts of the protective device are in the closed position. The rod has a diameter of 76 mm i 0.1 mm and a flat end. There shall be a distance of at least 1,5 mm between the rod and the button.
The protectIve device shall not be prevented from operating with the rod applied and shall not automatically reset.
22.103 Appliances shall be so constructed that the feed chamber and guards can be cleaned.
Corn plance is checked by Inspection.