3.102
booster setting
position of a control resulting In a temporary higher power input that is automatically reduced to the power input value when the setting is not used
3.103
centrally-sited vacuum cleaner
vacuum cleaner that Is connected to a ducting system Installed In the building
NOTE During use, the nozzle and its associated hose are connected to one of the auction inlets of the ducting system
3.104
motorized cleaning head
accessory containing a motor that is supplied from the vacuum cleaner and which is attached to the end of a hose or tube
4 General requirement
This clause of Part I is applicable.
5 General conditions for the tests
This clause of Part 1 is applicable except as follows.
5.2 Addition:
A new hose is used for each of the tests of 21.101 to 21.104.
5.101 Current-carrying hoses operating at safety extra-low voltage are not subjected to the tests of 21.101 to 21.104.
6 ClassificatIon
This clause of Part I is applicable except as follows.
6.1 Modification:
Vacuum cleaners and water-suctIon cleaning applIances shall be class I. class II or class Ill.
Vacuum cleaners for animal grooming shall be class II or class lll
6.2 Addition:
Vacuum cleaners for animal grooming and water-suction cleaning appliances shall be at least IPX4.
NOTE This symbol a an information sign and, sxc.pt fo he colours. lii. rules 04 ISO 3864 apply,
Compliance is checked by inspection.
7.102 Appliance outlets for accessories shall be marked with the maximum load in watts.
NOTE This mavIing mat, be on the appliance close to the appliance outlet
Compliance is checked by inspection.
8 Protection against access to live parts
This clause of Part I is applicable except as follows.
8.1.1 Addition:
If the instructions state that a part is to be removed when replacing a lamp o a drive belt, and
a tool Is required for Its removal, the part is not considered to be a d.tachabl. part provided
— an instruction to disconnect the appliance from the supply before opening is marked on the cover or is visible during its removal, and
– after removal of the cover, access to llv• parts is prevented by at least basIc Insulation
9 Starting of motor-operated appliances
This clause of Part 1 is not applicable.
10 Power input and current
This clause of Part 1 is applicable except as follows.
10.1 Addition:
The power input of motorized cleaning heeds is measured separately.
NOTE 101 ApplIance outlets are no4 loaded when measuring the rated power Inpul.
Booster settings are not used during these measurements.
11 Heating
This clause of Part 1 is applicable except as follows.
11.3 Addition
NOTE 101 When measuring the power input to ensure that the appliance has been correctly reassembled, the power input P wIth the air-Inlet bloclied I. measured
11.5 Addition:
Booster settings are activated as often as allowed by the construction,
11.7 Addition:
Appliances are operated until steady conditions are established.
Appliances incorporating an automatic cord reel are operated with one-third of the total length
of the cord unreeled for 30 mEn, after which the cord Is completely unreeled. 12 Void
13 Leakage current and electric strength at operating temperature This clause of Part 1 is applicable except as follows.
13.1 Addition:
NOTE 101 Boot.r eIUngs ara no used.
14 TransIent overvoltages
This clause of Part I is applicable.
15 Moisture resistance
This clause of Part 1 is applicable except as follows.
15,2 Replacement:
Appliances having a liquid container shall be constructed so that spillage of liquid due to overfilling, and due to overturning of appliances liable to be overturned in normal use, does not affect their electrical insulation.
Compliance is checked by the following test.
The liquid container is filled with water to half the level indicated in the instructions. The appliance is placed on a support inclined at an angle or io to the horizontal. A force of 180 N Es applied to the top of the appliance In the most unfavourable horizontal direction, lithe appliance overturns, it is considered to be liable to be overturned in normal use.
Appliances with type X attachment, except those having a specially prepared cord, are fitted with the lightest permissible type of flexible cord of the smallest cross-sectional area specified In Table 13.
Appliances incorporating en appliance inlet are tested with or without an appropriate connector in position, whichever is more unfevourabte.
Liquid containers that are filled by hand are completely filled with water containing approximately I % NaCI and a further quantity, equal to 15 % of the capacity of the container or 0.25 I. whichever is the greater, is poured in steadily over a period of 1 min.