Home>SAE Standards>SAE J561 pdf download

SAE J561 pdf download

SAE J561 pdf download.Electrical Terminals—Eyelet and Spade Type.
2. References
2.1 Applicable Publication—The following publications form a part of this specification to the extent specified herein, The latest issue of SAE publications shall apply
21.1 SAE RJBLicAnoN—Available from SAE. 400 Commonwealth Drive. Warrendale, PA 15096-0001.
SAE J163—Low Tension Wiring and Cable Terminals and Splice Clips
3. General Requfrements—The eyelet and spade type terminals listed in Tables 1A and lB and Figures 1 through 5 of this document may be used for terminating wire ends or for terminating circuits on devices other than wire. Performance requirements for low tension wire terminals are specified In SAE J163.
Terminal sizes other than those listed are permissible, providing they meet the general requirements of this document and the performance requwernents of SAE ,J163.
Terminals shall be free from burrs, corrosion, or any foreign matter, and shall be of a temper that will permit attachment to wi-es or circuits on devices without fracturing or cracking.
Terminals may be applied to wire by crinping, welding. swaging, soldering, or any combination thereof at the conductor grip Insulation grips shall be used on all terminals assembled to 8 gage (8 mm2) and smaller insulated wire except where usage provides other means of relieving strain, Materials should be of copper. brass, or other copper alloys. Minimum metal thickness is the nominal thickness shown less a standard strip stock tolerance. Thickness is based on SAE CA260 (UNS C26000) brass conductivity and may be adjusted for use with other materials. Unless otherwise noted, all dimensions shall be held to a tolerance of ± 025 mm (t 0010 in).

Related Standards